Installation points of parking heater. It's time to talk about the relevant knowledge of the parking heater. Next, let's talk about the installation points of the parking heater for you.
1、 Fixation of oil pot and oil pump:
The position of the oil pot shall be fixed to facilitate the subsequent filling of fuel, and at the same time, it shall not affect the lifting of the vehicle head.
Suggestions for installation of oil pump: the oil outlet shall be higher than the oil inlet, with an included angle of 45 ° -60 °.
2、 Fixing of intake pipe, exhaust pipe and oil pipe:
The difference between the inlet pipe and the outlet of the exhaust pipe shall be more than 15cm to prevent the exhaust gas from being sucked into the machine again
The temperature of the exhaust pipe will reach about 200 ° when the heater is working. Therefore, when fixing the exhaust pipe, avoid the lines and oil circuits. If conditions permit, blow the engine.
3、 Host fixation:
The following points shall be paid attention to when fixing the host:
First, the main engine must be stable. There are two main installation methods for the main engine. The most commonly used one is the installation method in the diagram. The exhaust pipe is installed vertically. The other is the vertical installation method between the exhaust pipe and the vehicle wall. However, the installation requirements of this method are high, and the glow plug port must be upward, otherwise there will be fuel overflow, which has great potential safety hazards.
Second: the air inlet of the main engine must have an air inlet distance of more than 5cm, and the air outlet should also be kept unobstructed. Of course, there should be no things on the heater, so as to avoid the high-temperature shutdown of the body or even the baking deformation of the thermosetting plastic shell during the working process of the heater.
Third: the installation of the parking heater should take into account the maintenance situation, so try to leave more than 5cm of the left and right space of the machine body to ensure convenient maintenance. Webstone shared the installation points of the parking heater, hoping to help you.