News

Common fault analysis of parking heater:

Common fault analysis of parking heater:

1. If the indicator light flashes, you can check the flashing frequency and judge the fault location according to the fault flash code table. If the indicator lights up frequently, it may be that the control circuit is broken or the ground wire is not connected, and the corresponding components can be repaired or replaced.

2. If the ignition plug is damaged, use a multimeter to check the resistance between the two leads of the ignition plug. The resistance should be between 0.6-1.2 ohms. If it is not within this range, replace the ignition plug.

3. The heater is overheated, the radiator and defroster are not hot, and the circulating pipe may be blocked by foreign matters; The hose is bent; Water pump failure; There is gas in the circulating water circuit; The inlet and return water valves are not opened, and the engine thermostat is opened too early. Find out the cause and carry out corresponding maintenance.

The reason why the parking heater does not fire may be that there is no fuel in the fuel tank. Just check whether the fuel is sufficient and add it in time. Or it may be that the oil pipe is blocked and damaged. It is necessary to check whether there are foreign matters in the oil pipe and whether the joints are loose. Replace or clean the parts in time.